| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Density | DIN EN ISO 1183-1 | g / cm3 | >0,90 | 
| Water absorption | DIN EN ISO 62 | % | 0,1 | 
| Flammability (Thickness 3 mm / 6 mm) | UL 94 | HB | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Yield stress | DIN EN ISO 527 | MPa | >30 | 
| Elongation at break | DIN EN ISO 527 | % | >50 | 
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | >1500 | 
| Notched impact strength | DIN EN ISO 179 | kJ / m2 | >4 | 
| Shore hardness | DIN EN ISO 868 | scale D | >70 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Melting temperature | ISO 11357-3 | °C | 162 ... 167 | 
| Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,20 | 
| Thermal capacity | DIN 52612 | kJ / (kg * K) | 1,70 | 
| Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 120 ... 190 | 
| Service temperature, long term | Average | °C | 0 … 120 | 
| Service temperature, short term (max.) | Average | °C | 150 | 
| Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 90 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Dielectric constant | IEC 60250 | 2,4 | |
| Dielectric dissipation factor (106 Hz) | IEC 60250 | 0,00019 | |
| Volume resistivity | DIN EN 62631-3-1 | Ω * cm | >1014 | 
| Surface resistivity | DIN EN 62631-3-2 | Ω | >1014 | 
| Dielectric strength | IEC 60243 | kV / mm | >40 |